<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:georss="http://www.georss.org/georss" xmlns:geo="http://www.w3.org/2003/01/geo/wgs84_pos#" xmlns:media="http://search.yahoo.com/mrss/"
		>
<channel>
	<title>Komentar di: Menghitung Daya Listrik</title>
	<atom:link href="http://kapilo0o.wordpress.com/2008/02/08/menghitung-daya-listrik/feed/" rel="self" type="application/rss+xml" />
	<link>http://kapilo0o.wordpress.com/2008/02/08/menghitung-daya-listrik/</link>
	<description></description>
	<lastBuildDate>Mon, 19 Oct 2009 09:13:03 +0000</lastBuildDate>
	<generator>http://wordpress.com/</generator>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
		<item>
		<title>Oleh: Royvic</title>
		<link>http://kapilo0o.wordpress.com/2008/02/08/menghitung-daya-listrik/#comment-32</link>
		<dc:creator>Royvic</dc:creator>
		<pubDate>Mon, 19 Oct 2009 09:13:03 +0000</pubDate>
		<guid isPermaLink="false">http://kapilo0o.wordpress.com/2008/02/08/menghitung-daya-listrik/#comment-32</guid>
		<description>cara ngitung daya listrik 1 phasa :
P = Daya aktif  
V = Tegangan
I = Arus listrik

P= V x I x Cos phi

Cos phi = factor daya, dari PLN 0,85 udah top banget , ideal = 1, nyampe di rumah - rumah +/- 0,7 udah top dech, kalau mau detail ukur aje dengan cos phi meter

contoh : kalau kita punya TV 14&quot;, dayanya = 65 W, truss pompa = 350 w, lampu neon ada 10 @10w = 100w
jadi Total beban = 65 + 350 +100 = 515 watt (artinya pemakaian bebannya = 515 watt), truss tegangan kan nga berubah = 220 V, jadi arus listriknya I = P/V x cos phi = 515/220 x 0,7 = 3,34 A artinya MCB pake yg 4 Ampere 
(3,34 dibulatkan jadi 4 krn mcb nga ada yg 3,34 A) 

jadi temen 2x kalau mau MCB nga turun-turun itung dulu Beban daya listriknya baru pake dech cara diatas untuk cari MCB berapa yg mau di pake.....gitu aje ! 

Thank&#039;s</description>
		<content:encoded><![CDATA[<p>cara ngitung daya listrik 1 phasa :<br />
P = Daya aktif<br />
V = Tegangan<br />
I = Arus listrik</p>
<p>P= V x I x Cos phi</p>
<p>Cos phi = factor daya, dari PLN 0,85 udah top banget , ideal = 1, nyampe di rumah &#8211; rumah +/- 0,7 udah top dech, kalau mau detail ukur aje dengan cos phi meter</p>
<p>contoh : kalau kita punya TV 14&#8243;, dayanya = 65 W, truss pompa = 350 w, lampu neon ada 10 @10w = 100w<br />
jadi Total beban = 65 + 350 +100 = 515 watt (artinya pemakaian bebannya = 515 watt), truss tegangan kan nga berubah = 220 V, jadi arus listriknya I = P/V x cos phi = 515/220 x 0,7 = 3,34 A artinya MCB pake yg 4 Ampere<br />
(3,34 dibulatkan jadi 4 krn mcb nga ada yg 3,34 A) </p>
<p>jadi temen 2x kalau mau MCB nga turun-turun itung dulu Beban daya listriknya baru pake dech cara diatas untuk cari MCB berapa yg mau di pake&#8230;..gitu aje ! </p>
<p>Thank&#8217;s</p>
]]></content:encoded>
	</item>
	<item>
		<title>Oleh: Azzy</title>
		<link>http://kapilo0o.wordpress.com/2008/02/08/menghitung-daya-listrik/#comment-19</link>
		<dc:creator>Azzy</dc:creator>
		<pubDate>Mon, 09 Feb 2009 10:39:29 +0000</pubDate>
		<guid isPermaLink="false">http://kapilo0o.wordpress.com/2008/02/08/menghitung-daya-listrik/#comment-19</guid>
		<description>Sudah pasti MCB turun trus kelebihan beban... CPU+Monitor kurang lebih dayanya 150 watt(VA) kali 15 = 2250 watt(VA)
di tambah kulkas (&lt; 100 VA) dan pompa (&lt; 300), gak cukup lah.......
2200 VA itu kan MCB 10 Amper, mau aman pakai MCB 16 Amper.</description>
		<content:encoded><![CDATA[<p>Sudah pasti MCB turun trus kelebihan beban&#8230; CPU+Monitor kurang lebih dayanya 150 watt(VA) kali 15 = 2250 watt(VA)<br />
di tambah kulkas (&lt; 100 VA) dan pompa (&lt; 300), gak cukup lah&#8230;&#8230;.<br />
2200 VA itu kan MCB 10 Amper, mau aman pakai MCB 16 Amper.</p>
]]></content:encoded>
	</item>
	<item>
		<title>Oleh: wagimin</title>
		<link>http://kapilo0o.wordpress.com/2008/02/08/menghitung-daya-listrik/#comment-18</link>
		<dc:creator>wagimin</dc:creator>
		<pubDate>Wed, 21 Jan 2009 14:58:22 +0000</pubDate>
		<guid isPermaLink="false">http://kapilo0o.wordpress.com/2008/02/08/menghitung-daya-listrik/#comment-18</guid>
		<description>saya punya warnet denag kapasitas daya 2200va dipakai untuk:

1. 15 komputer stiap komputr {cpu 450w monitor 75W}
 2. kulkas 2
 pompa air 1
yng saya tanyakan  knapa Mcb nya sering turun
 apakah kelebihan beban atau mcbnya jelek
 terimaklasih</description>
		<content:encoded><![CDATA[<p>saya punya warnet denag kapasitas daya 2200va dipakai untuk:</p>
<p>1. 15 komputer stiap komputr {cpu 450w monitor 75W}<br />
 2. kulkas 2<br />
 pompa air 1<br />
yng saya tanyakan  knapa Mcb nya sering turun<br />
 apakah kelebihan beban atau mcbnya jelek<br />
 terimaklasih</p>
]]></content:encoded>
	</item>
	<item>
		<title>Oleh: Azzy</title>
		<link>http://kapilo0o.wordpress.com/2008/02/08/menghitung-daya-listrik/#comment-15</link>
		<dc:creator>Azzy</dc:creator>
		<pubDate>Thu, 09 Oct 2008 06:29:37 +0000</pubDate>
		<guid isPermaLink="false">http://kapilo0o.wordpress.com/2008/02/08/menghitung-daya-listrik/#comment-15</guid>
		<description>maksud gimana sih...!!saya belum pernah melihat meteran listrik di pabrik jadi tidak tahu...mungkin caranya bisa sama seperti saya atau untuk arus yg besar seperti di pabrik bisa menggunakan tang amper lebih mudah.</description>
		<content:encoded><![CDATA[<p>maksud gimana sih&#8230;!!saya belum pernah melihat meteran listrik di pabrik jadi tidak tahu&#8230;mungkin caranya bisa sama seperti saya atau untuk arus yg besar seperti di pabrik bisa menggunakan tang amper lebih mudah.</p>
]]></content:encoded>
	</item>
	<item>
		<title>Oleh: kutu busuk</title>
		<link>http://kapilo0o.wordpress.com/2008/02/08/menghitung-daya-listrik/#comment-8</link>
		<dc:creator>kutu busuk</dc:creator>
		<pubDate>Tue, 10 Jun 2008 03:53:48 +0000</pubDate>
		<guid isPermaLink="false">http://kapilo0o.wordpress.com/2008/02/08/menghitung-daya-listrik/#comment-8</guid>
		<description>mas kalo seumpama dimeterannya terdapat CT= current transformer...seperti yg di industri, 
karena arus yg mengalir pada industri terlalu besar maka di turunkan untuk pengukuranya menjadi i max. nominal 5 ampere.
gimana cara hitungnya...thank&#039;s</description>
		<content:encoded><![CDATA[<p>mas kalo seumpama dimeterannya terdapat CT= current transformer&#8230;seperti yg di industri,<br />
karena arus yg mengalir pada industri terlalu besar maka di turunkan untuk pengukuranya menjadi i max. nominal 5 ampere.<br />
gimana cara hitungnya&#8230;thank&#8217;s</p>
]]></content:encoded>